Hokkaido University Collection of Scholarly and Academic Papers >
Graduate School of Medicine / Faculty of Medicine >
Peer-reviewed Journal Articles, etc >
Right ventricular pressure-volume loop produced with simultaneous application of three-dimensional echocardiography and high-fidelity micromanometry in a patient with pulmonary arterial hypertension
Title: | Right ventricular pressure-volume loop produced with simultaneous application of three-dimensional echocardiography and high-fidelity micromanometry in a patient with pulmonary arterial hypertension |
Authors: | Nakaya, Toshitaka Browse this author | Tsujino, Ichizo Browse this author →KAKEN DB | Nakamura, Junichi Browse this author | Chiba, Yasuyuki Browse this author | Iwano, Hiroyuki Browse this author |
Keywords: | pulmonary hypertension | right ventricular function | three-dimensional echocardiography |
Issue Date: | 24-May-2021 |
Publisher: | John Wiley & Sons |
Journal Title: | Echocardiography-a journal of cardiovascular ultrasound and allied techniques |
Volume: | 38 |
Issue: | 5 |
Start Page: | 805 |
End Page: | 807 |
Publisher DOI: | 10.1111/echo.15032 |
Abstract: | Accurate assessment of right ventricular (RV) function has received a growing attention. Pressure-volume (PV) loop analysis is the gold standard method for evaluating RV function; however, it is not widely employed because of its invasive nature and complexity. The present report is the first to have drawn a RV PV loop in a patient with pulmonary hypertension, with a simultaneous recording of RV pressure and volume using high-fidelity micromanometry and three-dimensional echocardiography. This allows for less invasive and simple assessment of RV function, potentially promoting better understanding and management of pulmonary hypertension and other cardiovascular diseases. |
Rights: | This is the peer reviewed version of the following article: Chiba Y, Iwano H. Right Ventricular pressure– volume loop produced with simultaneous application of three-dimensional echocardiography and high- fidelity micromanometry in a patient with pulmonary arterial hypertension. Echocardiography. 2021;38:805– 807, which has been published in final form at https://doi.org/10.1111/echo.15032. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions |
Type: | article (author version) |
URI: | http://hdl.handle.net/2115/85666 |
Appears in Collections: | 医学院・医学研究院 (Graduate School of Medicine / Faculty of Medicine) > 雑誌発表論文等 (Peer-reviewed Journal Articles, etc)
|
Submitter: 辻野 一三
|