HUSCAP logo Hokkaido Univ. logo

Hokkaido University Collection of Scholarly and Academic Papers >
医学研究院・医学院  >
雑誌発表論文等  >

Multidirectional flexibility analysis of anterior and posterior lumbar artificial disc reconstruction: in vitro human cadaveric spine model.

フルテキスト
ESJ.pdf1.25 MBPDF見る/開く
この文献へのリンクには次のURLを使用してください:http://hdl.handle.net/2115/14768

タイトル: Multidirectional flexibility analysis of anterior and posterior lumbar artificial disc reconstruction: in vitro human cadaveric spine model.
著者: Kotani, Yoshihisa 著作を一覧する
Cunningham, Bryan W. 著作を一覧する
Abumi, Kuniyoshi 著作を一覧する
Dmitriev, Anton E. 著作を一覧する
Hu, Niabin 著作を一覧する
Ito, Manabu 著作を一覧する
Shikinami, Yasuo 著作を一覧する
McAfee, Paul C. 著作を一覧する
Minami, Akio 著作を一覧する
キーワード: Artificial intervertebral disc
Lumbar spine
Biomechanics
発行日: 2006年
出版者: Springer Berlin / Heidelberg
誌名: European Spine Journal
巻: 15
号: 10
開始ページ: 1511
終了ページ: 1520
出版社 DOI: 10.1007/s00586-006-0086-z
抄録: The in vitro multidirectional flexibility analysis was conducted to investigate the initial biomechanical effect of biomimetic artificial intervertebral disc replacement from either anterior or posterior approach in a cadaveric lumbosacral spine model. Two designs of anterior total and posterior subtotal artificial discs were developed using bioactive three-dimensional fabric and bioresorbable hydroxyapatite/poly-l-lactide material (3DF disc). Both models were designed to obtain the stable interface bonding to vertebral endplates with maximum surface area occupation. Using seven cadaveric lumbosacral spines, the following three anterior reconstruction methods were sequentially performed at L4–5 level: anterior 3DF disc replacement; anterior BAK cages (BAK); and posterior pedicle screw fixation and anterior BAK cages combined (BAK + PS). The L2–3 level received two methods of posterior reconstructions: subtotal 3DF disc replacement (two implants), and posterior interbody cages and pedicle screw fixation (PLIF). Six unconstrained pure moments were applied and three-dimensional segmental motions were measured with an optoelectronic motion measurement system. The center of rotation (COR) calculation was conducted radiographically using flexion-extension films. Both anterior and posterior 3DF replacements statistically demonstrated equivalent range of motions (ROMs) in all loading modes compared to intact segment. Anterior BAK, BAK + PS, and PLIF demonstrated significantly lower ROMs when compared to intact and 3DF groups (P<0.05). The 3DF reconstruction tended to realign the COR to the posterior third or surrounding position at the operative disc level. The stand-alone lumbar 3DF disc replacement demonstrated biomechanical characteristics nearly equivalent to the intact spinal segments even through anterior or posterior approach in vitro, suggesting an excellent clinical potential.
Rights: The original publication is available at www.springerlink.com
資料タイプ: article (author version)
URI: http://hdl.handle.net/2115/14768
出現コレクション:雑誌発表論文等 (Peer-reviewed Journal Articles, etc)

提供者: 小谷 善久

 

本サイトに関するご意見・お問い合わせは repo at lib.hokudai.ac.jp へお願いします。 - 北海道大学