HUSCAP logo Hokkaido Univ. logo

Hokkaido University Collection of Scholarly and Academic Papers >
Graduate School of Veterinary Medicine / Faculty of Veterinary Medicine >
Peer-reviewed Journal Articles, etc >

Seasonal efficiency of a hybrid sub-surface flow constructed wetland system in treating milking parlor wastewater at northern Hokkaido

Files in This Item:
seasonal variation_Preadeep etal.2013.pdf310.3 kBPDFView/Open
Please use this identifier to cite or link to this item:http://hdl.handle.net/2115/53736

Title: Seasonal efficiency of a hybrid sub-surface flow constructed wetland system in treating milking parlor wastewater at northern Hokkaido
Authors: Sharma, Pradeep Kumar Browse this author
Takashi, Inoue Browse this author →KAKEN DB
Kato, Kunihiko Browse this author
Ietsugu, Hidehiro Browse this author
Tomita, Kunihiko Browse this author
Nagasawa, Tetsuaki Browse this author
Keywords: Hybrid sub-surface CWs
Cold climate
Seasonal variation
Milking parlor wastewater
Issue Date: Apr-2013
Publisher: ELSEVIER SCIENCE BV
Journal Title: ECOLOGICAL ENGINEERING
Volume: 53
Start Page: 257
End Page: 266
Publisher DOI: 10.1016/j.ecoleng.2012.12.054
Abstract: This paper presents the effects of seasonal variations on the purification and removal efficiencies of a hybrid sub-surface CW system (VF-VF-HF) treating milking parlor wastewater at northern Hokkaido, Japan. VF(a) and VF(b) are gravel beds, each 160 m(2) in size whereas HF is sand bed and 336 m(2) in size. Daily mean air temperature at site showed a difference of 16 degrees C between warm (May-October) and cold (November-April) periods. Average influent concentrations for cold and warm periods were: CODCr: 3749 and 4988 mg L-1; BOD5: 1637 and 1395 mg L-1; TSS: 661 and 862 mg L-1; TN: 161 and 194 mg L-1; TP: 23.9 and 31.9 mg L-1 and total carbon: 1212 and 1715 mg L-1. Average purification rates of BOD5, TSS, TP, PO4-P and total carbon fluctuated <2.5% between both periods. However purification rates of NH4-N and Organic-P decreased by 9.5% and 12% respectively during warm period. Average removal rates of TSS and BOD5 were unaffected between both periods, while that of CODCr, TN, total carbon increased by 3-4% during warm period. Hybrid sub-surface CW system achieved purification and removal rates of >95% for TSS and total coliform; >89% for CODCr and BOD5; >76% for TN and >72% for TP during both cold and warm periods. (C) 2012 Elsevier B.V. All rights reserved.
Type: article (author version)
URI: http://hdl.handle.net/2115/53736
Appears in Collections:獣医学院・獣医学研究院 (Graduate School of Veterinary Medicine / Faculty of Veterinary Medicine) > 雑誌発表論文等 (Peer-reviewed Journal Articles, etc)

Submitter: 井上 京

Export metadata:

OAI-PMH ( junii2 , jpcoar_1.0 )

MathJax is now OFF:


 

 - Hokkaido University