HUSCAP logo Hokkaido Univ. logo

Hokkaido University Collection of Scholarly and Academic Papers >
Graduate School of Fisheries Sciences / Faculty of Fisheries Sciences >
北海道大学水産科学研究彙報 = Bulletin of Fisheries Sciences, Hokkaido University >
第68巻 第2号 >

Stereospecific Analysis of Fish Oil Triacylglycerols by Silicic Acid HPLC Using Monoacylglycerol Analytical Intermediates

Files in This Item:
bull.fish.68.2.33.pdf933.98 kBPDFView/Open
Please use this identifier to cite or link to this item:https://doi.org/10.14943/bull.fish.68.2.33

Title: Stereospecific Analysis of Fish Oil Triacylglycerols by Silicic Acid HPLC Using Monoacylglycerol Analytical Intermediates
Authors: Ando, Yasuhiro Browse this author →KAKEN DB
Matsumoto, Nobuto Browse this author
Yoneta, Yukino Browse this author
Tada, Naoto Browse this author
Keywords: Fish oil
Triacylglycerol
Stereospecific analysis
HPLC
1-(1-Naphthyl)ethyl urethane
Issue Date: 2-Aug-2018
Publisher: 北海道大学大学院水産科学研究院
Journal Title: 北海道大学水産科学研究彙報
Volume: 68
Issue: 2
Start Page: 33
End Page: 41
Abstract: This study establishes a method for the stereospecific analysis of fish oil triacylglycerols (TAG) using silicic acid high-performance liquid chromatography (HPLC). The analysis includes partial degradation of TAG to monoacylglycerols (MAG), derivatization of MAG to (R)-(−)-1-(1-naphthyl)ethyl urethanes, fractionation of sn-1-, sn-2-, and sn-3-MAG by HPLC, and fatty acid analysis of methyl esters by gas chromatography. For the analysis of fish oil TAG, several modifications were required in the original method developed for the analysis of olive oil TAG. For the HPLC analysis, reducing the proportion of 2-propanol in the mobile phase enabled clear separation of sn-1- and sn-3-MAG, which consisted of a wide variety of fatty acids of fish origin. Another improvement that was made was purifying the fatty acid methyl esters prepared from MAG urethanes by thin-layer chromatography. Stereospecific analysis was achieved when commencing with only 1 mg of fish oil TAG. Acyl migration, which affects the accuracy of the analysis, was found to be less than 5%. Using this method, stereospecific analysis can be carried out by HPLC on a conventional silica column, in contrast to the conventional HPLC method that requires expensive chiral columns. This method can also be used for the analysis of the TAG of both common and rare fish.
Type: bulletin (article)
URI: http://hdl.handle.net/2115/71151
Appears in Collections:北海道大学水産科学研究彙報 = Bulletin of Fisheries Sciences, Hokkaido University > 第68巻 第2号

Export metadata:

OAI-PMH ( junii2 , jpcoar_1.0 )

MathJax is now OFF:


 

 - Hokkaido University