HUSCAP logo Hokkaido Univ. logo

Hokkaido University Collection of Scholarly and Academic Papers >
Graduate School of Health Sciences / Faculty of Health Sciences >
Peer-reviewed Journal Articles, etc >

Detection of Fine Radiographic Progression in Finger Joint Space Narrowing Beyond Human Eyes: Phantom Experiment and Clinical Study with Rheumatoid Arthritis Patients

This item is licensed under:Creative Commons Attribution 4.0 International

Files in This Item:

The file(s) associated with this item can be obtained from the following URL: https://doi.org/10.1038/s41598-019-44747-6


Title: Detection of Fine Radiographic Progression in Finger Joint Space Narrowing Beyond Human Eyes: Phantom Experiment and Clinical Study with Rheumatoid Arthritis Patients
Authors: Kato, Kazuki Browse this author
Yasojima, Nobutoshi Browse this author
Tamura, Kenichi Browse this author
Ichikawa, Shota Browse this author
Sutherland, Kenneth Browse this author →KAKEN DB
Kato, Masaru Browse this author →KAKEN DB
Fukae, Jun Browse this author
Tanimura, Kazuhide Browse this author
Tanaka, Yuki Browse this author →KAKEN DB
Okino, Taichi Browse this author
Lu, Yutong Browse this author
Kamishima, Tamotsu Browse this author →KAKEN DB
Issue Date: 12-Jun-2019
Publisher: Nature Publishing Group
Journal Title: Scientific reports
Volume: 9
Start Page: 8526
Publisher DOI: 10.1038/s41598-019-44747-6
Abstract: The visual assessment of joint space narrowing (JSN) on radiographs of rheumatoid arthritis (RA) patients such as the Genant-modified Sharp score (GSS) is widely accepted but limited by its subjectivity and insufficient sensitivity. We developed a software application which can assess JSN quantitatively using a temporal subtraction technique for radiographs, in which the chronological change in JSN between two radiographs was defined as the joint space difference index (JSDI). The aim of this study is to prove the superiority of the software in terms of detecting fine radiographic progression in finger JSN over human observers. A micrometer measurement apparatus that can adjust arbitrary joint space width (JSW) in a phantom joint was developed to define true JSW. We compared the smallest detectable changes in JSW between the JSDI and visual assessment using phantom images. In a clinical study, 222 finger joints without interval score change on GSS in 15 RA patients were examined. We compared the JSDI between joints with and without synovial vascularity (SV) on power Doppler ultrasonography during the follow-up period. True JSW difference was correlated with JSDI for JSW differences ranging from 0.10 to 1.00 mm at increments of 0.10 mm (R-2 = 0.986 and P < 0.001). Rheumatologists were difficult to detect JSW difference of 0.30 mm or less. The JSDI of finger joints with SV was significantly higher than those without SV (P = 0.030). The software can detect fine differences in JSW that are visually unrecognizable.
Rights: https://creativecommons.org/licenses/by/4.0/
Type: article
URI: http://hdl.handle.net/2115/75011
Appears in Collections:保健科学院・保健科学研究院 (Graduate School of Health Sciences / Faculty of Health Sciences) > 雑誌発表論文等 (Peer-reviewed Journal Articles, etc)

Export metadata:

OAI-PMH ( junii2 , jpcoar_1.0 )

MathJax is now OFF:


 

 - Hokkaido University