Hokkaido University Collection of Scholarly and Academic Papers >
Graduate School of Dental Medicine / Faculty of Dental Medicine >
Peer-reviewed Journal Articles, etc >
Laser-Induced Forward Transfer with Optical Stamp of a Protein-Immobilized Calcium Phosphate Film Prepared by Biomimetic Process to a Human Dentin
This item is licensed under:Creative Commons Attribution 4.0 International
Title: | Laser-Induced Forward Transfer with Optical Stamp of a Protein-Immobilized Calcium Phosphate Film Prepared by Biomimetic Process to a Human Dentin |
Authors: | Narazaki, Aiko Browse this author | Oyane, Ayako Browse this author | Miyaji, Hirofumi Browse this author →KAKEN DB |
Keywords: | laser-induced forward transfer | calcium phosphate | cell adhesion protein | biomimetic process | optical stamp | human dentin | interface observation |
Issue Date: | 11-Nov-2020 |
Publisher: | MDPI |
Journal Title: | Applied Sciences |
Volume: | 10 |
Issue: | 22 |
Start Page: | 7984 |
Publisher DOI: | 10.3390/app10227984 |
Abstract: | The rapid and area-specific printing of calcium phosphate with superior biocompatibility and osteoconductivity is a useful technique for the surface functionalization of biomedical devices. We recently demonstrated the laser-induced forward transfer (LIFT) of a brittle calcium phosphate film onto a soft and shock-absorbing polydimethylsiloxane (PDMS) substrate. In this work, a new LIFT using an optically transparent PDMS-coated stamp, which we hereafter call LIFT with optical stamp (LIFTOP), was introduced to achieve the transfer of brittle films to harder substrates. Cell adhesion protein fibronectin-immobilized calcium phosphate films (Fn-CaP) were prepared on the optical stamp through a biomimetic process. Then, the irradiation of a single laser pulse transferred the Fn-CaP film from the optical stamp onto relatively hard substrates, polyethylene terephthalate and human dentin. As a result of this LIFTOP process, Fn-CaP microchips with a shape corresponding to the laser beam spot were printed on the substrates. Cross-sectional observation of the interface between the Fn-CaP microchip and the dentin substrate revealed good attachment between them without obvious gaps for the most part. |
Rights: | © 2000 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/). | https://creativecommons.org/licenses/by/4.0/ |
Type: | article |
URI: | http://hdl.handle.net/2115/79788 |
Appears in Collections: | 歯学院・歯学研究院 (Graduate School of Dental Medicine / Faculty of Dental Medicine) > 雑誌発表論文等 (Peer-reviewed Journal Articles, etc)
|
Submitter: 宮治 裕史
|