Accuracy of the Data of Biochemical Parameters in Blood Collected Above the Infusion Insertion Site
Title: | Accuracy of the Data of Biochemical Parameters in Blood Collected Above the Infusion Insertion Site |
Authors: | Koike, Shotaro Browse this author →KAKEN DB | Sasaki, Shinsuke Browse this author →KAKEN DB | Yano, Rika Browse this author →KAKEN DB |
Keywords: | biochemical test | blood collection | blood count | intravenous infusion |
Issue Date: | Mar-2022 |
Publisher: | Lippincott Williams & Wilkins (LWW) |
Journal Title: | Journal of Infusion Nursing |
Volume: | 45 |
Issue: | 2 |
Start Page: | 81 |
End Page: | 87 |
Publisher DOI: | 10.1097/NAN.0000000000000456 |
PMID: | 35272304 |
Abstract: | The authors aimed to investigate the possibility of collecting blood samples from above patient intravenous infusion sites by temporarily stopping the infusions while collecting the blood. A hypotonic infusion solution was administered to 5 male patients through the cephalic veins in the forearms of their left upper limbs. The biochemical data of blood collected from the median cubital veins of both patients' arms were compared. The results showed that infusions could change some biochemical test parameters, such as potassium and glucose, to higher levels, even if the infusion was interrupted temporarily during the blood collection from above the insertion site. Blood counts remained unchanged under the same conditions. If the evaluation is performed solely to assess blood counts, using a blood collection site above the insertion site by temporarily interrupting the infusion is feasible. |
Type: | article |
URI: | http://hdl.handle.net/2115/85071 |