Changes in mass and stress during anodic oxidation and cathodic reduction of the Cu/Cu2O multilayer film

Files in This Item:
CS49-1.pdf710.55 kBPDFView/Open
Please use this identifier to cite or link to this item:http://hdl.handle.net/2115/18855

Title: Changes in mass and stress during anodic oxidation and cathodic reduction of the Cu/Cu2O multilayer film
Authors: Seo, Masahiro Browse this author
Hagioi, Machiko Browse this author
Keywords: A. Cu/Cu2O multilayer film
B. EQCM
B. Bending beam method
B. Gravimetry
B. Stress measurement
C. Anodic oxidation
C. Cathodic reduction
Issue Date: Jan-2007
Publisher: Elsevier Ltd
Journal Title: Corrosion Science
Volume: 49
Issue: 1
Start Page: 176
End Page: 185
Publisher DOI: 10.1016/j.corsci.2006.05.016
Abstract: The anodic oxidation and cathodic reduction processes of the Cu/Cu2O multilayer film and pure Cu film in pH 8.4 borate buffer solution were analyzed by electrochemical quartz crystal microbalance (EQCM) for gravimetry and bending beam method (BBM) for stress measurement. The mass loss of the multilayer film during anodic oxidation at 0.8 V (SHE) in the passive region was less than that of the pure Cu film. The comparison between current transients and mass changes during anodic oxidation has succeeded in separating the anodic current density into two partial current densities of oxide film growth, iO2-, and of Cu2+ dissolution through the passive film, iCu2+. As a result, in the case of the pure Cu film, the anodic current density was mainly due to iCu2+, while in the case of the multilayer film, iCu2+ was almost equal to iO2-. The compressive stress for the multilayer film was generated during anodic oxidation, while the tensile stress for the pure Cu film was generated. The mass loss of the multilayer film during cathodic reduction at a constant current density (ic = −20 μA cm−2) was significantly less than that estimated from coulometry, suggesting that H2O produced by cathodic reduction remained in the multilayer film. The compressive stress was generated during cathodic reduction of the multilayer film, which was ascribed to H2O remained in the multilayer film.
Relation: http://www.sciencedirect.com/science/journal/0010938X
Type: article (author version)
URI: http://hdl.handle.net/2115/18855
Appears in Collections:工学院・工学研究院 (Graduate School of Engineering / Faculty of Engineering) > 雑誌発表論文等 (Peer-reviewed Journal Articles, etc)