HUSCAP logo Hokkaido Univ. logo

Hokkaido University Collection of Scholarly and Academic Papers >
Graduate School of Science / Faculty of Science >
Peer-reviewed Journal Articles, etc >

In Situ Optical Second Harmonic Rotational Anisotropy Measurements of an Au(111) Electrode during Electrochemical Deposition of Tellurium

Files in This Item:
JPCB102-15_2677-2683.pdf85.31 kBPDFView/Open
Please use this identifier to cite or link to this item:http://hdl.handle.net/2115/50242

Title: In Situ Optical Second Harmonic Rotational Anisotropy Measurements of an Au(111) Electrode during Electrochemical Deposition of Tellurium
Authors: Yagi, Ichizo Browse this author
Nakabayashi, Seiichiro Browse this author
Uosaki, Kohei Browse this author →KAKEN DB
Issue Date: 9-Apr-1998
Publisher: American Chemical Society
Journal Title: Journal of Physical Chemistry B
Volume: 102
Issue: 15
Start Page: 2677
End Page: 2683
Publisher DOI: 10.1021/jp972763n
Abstract: The electrodeposition of Te on a single-crystalline Au(111) electrode was studied with 1064-nm-excited SH rotational anisotropy measurements. The SH rotational anisotropy was significantly changed with the first underpotential deposition (upd) of Te, and the bulk Te deposition attenuated the anisotropic character of the overall surface symmetry. The change in the SH rotational anisotropy during the first upd of Te was examined using two different models. The first model considered only the contribution of the Au(111) surface to the SHG response, while the second one took into account the contributions of both the Au(111) substrate and the adsorbed Te layer. In the former case, the change in the SH rotational anisotropy can be explained by considering the quenching of the nonlinear susceptibility of the Au(111) surface. The analysis based on the latter model resulted in a rotation angle of 608 for the adsorbed Te layer against the the Au(111) lattice. This value was not consistent with that expected from the adsorbate structure of the first upd layer of Te, i.e., (√3 x √3)R30°. Thus, the former model seems to be more appropriate to explain the present results. The SH rotational anisotropy measurement also suggests that the morphology became more isotropic after the bulk Te deposition.
Type: article
URI: http://hdl.handle.net/2115/50242
Appears in Collections:理学院・理学研究院 (Graduate School of Science / Faculty of Science) > 雑誌発表論文等 (Peer-reviewed Journal Articles, etc)

Submitter: 魚崎 浩平

Export metadata:

OAI-PMH ( junii2 , jpcoar_1.0 )

MathJax is now OFF:


 

 - Hokkaido University