Title: 高断熱・高気密住宅の室内環境と暖房エネルギー消費量に関する実態調査 : 札幌市内の北方型住宅を対象として
Other Titles: Actual condition survey on indoor environment and heating energy consumption for highly insulated and airtight houses: a study at northern regional houses in Sapporo
Authors: 菊田, 弘輝1 Browse this author →KAKEN DB
吉田, 卓生2 Browse this author
永沼, 純一3 Browse this author
羽山, 広文4 Browse this author →KAKEN DB
絵内, 正道5 Browse this author →KAKEN DB
阿部, 佑平6 Browse this author
Authors(alt): Kikuta, Kouki1
Yoshida, Takao2
Naganuma, Junichi3
Hayama, Hirofumi4
Enai, Masamichi5
Abe, Yuhei6
Keywords: Highly insulated and airtight house
Air convection
Whole-room heating
Heating energy consumption
高断熱高気密住宅
空気循環
全室暖房
暖房エネルギー消費量
Issue Date: Jan-2011
Publisher: 日本建築学会
Journal Title: 日本建築学会環境系論文集
Journal Title(alt): Transactions of AIJ. Journal of environmental engineering
Volume: 76
Issue: 659
Start Page: 17
End Page: 24
Publisher DOI: 10.3130/aije.76.17
Abstract: Mainly in Hokkaido, Q1 housing or housing for heating free and cooling free etc. have been advocated, which contributes to popularization of highly insulated and airtight houses. The aim of this study is to reveal the actual conditions on air convection or whole -room heating that contributes to creating a comfortable indoor environment and heating energy consumption at northern regional houses in Sapporo. Although we plan to aim at the housing performance such as Passive houses in Germany or Minergy houses in Switzerland etc. in the future, in order to attempt to raise the level of housing performance in stages in Japan, we mainly subject northern regional houses that have heat loss coefficient of around 1.0 W/m2 K and equivalent leakage area of 0.5 cm2/m2 or less.