Hokkaido University Collection of Scholarly and Academic Papers >
Graduate School of Engineering / Faculty of Engineering >
Peer-reviewed Journal Articles, etc >
北海道における集合住宅の南側共用廊下の熱環境とその設計法
Title: | 北海道における集合住宅の南側共用廊下の熱環境とその設計法 |
Other Titles: | ANALYSIS AND DESIGN METHOD OF THERMAL ENVIRONMENT IN SOUTHERN CORRIDOR ON AN APARTMENT HOUSE IN HOKKAIDO |
Authors: | 森, 太郎1 Browse this author →KAKEN DB | 辻, 圭輔2 Browse this author | 菅沼, 秀樹3 Browse this author | 羽山, 広文4 Browse this author →KAKEN DB | 菊田, 弘輝5 Browse this author →KAKEN DB |
Authors(alt): | Mori, Taro1 | Tsuji, Keisuke2 | Suganuma, Hideki3 | Hayama, Hirofumi4 | Kikuta, Koki5 |
Keywords: | Cold region | southern corridors on apartment house | thermal environment | solar radiation | 寒冷地 | 南側共用廊下 | 熱環境 | 日射 |
Issue Date: | 30-Apr-2012 |
Publisher: | 日本建築学会 |
Journal Title: | 日本建築学会環境系論文集 |
Journal Title(alt): | Transactions of AIJ. Journal of environmental engineering |
Volume: | 77 |
Issue: | 675 |
Start Page: | 357 |
End Page: | 363 |
Publisher DOI: | 10.3130/aije.77.357 |
Abstract: | Corridors on an apartment house are usually at indoor in Hokkaido. It can be achieved to make non-frozen and non-severe cold sharing space by installing those corridors on south side of apartment houses. Those places are useful for people in cold region. In this paper, the measurement results of thermal environment in the southern corridor at eastern Hokkaido is introduced. Also, the calculated result, thermal environment, by Esp-r and distribution of solar radiation by radiosity method are introduced.
We found the following as the result. 1) The temperatures in the southern corridors during daytime are over 15 degree Celsius in winter season. 2) Temperature without heating system can be predicted by simple heat balance equation. 3) Southern corridors in the Pacific ocean side region can maintain high temperature in winter season. 4) The results by radiosity method indicates a. high solar absorptance interior, b. narrow corridor, c. not-large window are effective to achieve high temperature in corridor and high transmittance into room simultaneously. Also, we suggested the simple calculation method for solar absorption and temperature without heating in southern corridors. |
Rights: | 日本建築学会 |
Type: | article |
URI: | http://hdl.handle.net/2115/52764 |
Appears in Collections: | 工学院・工学研究院 (Graduate School of Engineering / Faculty of Engineering) > 雑誌発表論文等 (Peer-reviewed Journal Articles, etc)
|
Submitter: 羽山 広文
|