HUSCAP logo Hokkaido Univ. logo

Hokkaido University Collection of Scholarly and Academic Papers >
Graduate School of Engineering / Faculty of Engineering >
Peer-reviewed Journal Articles, etc >

リポソームに内封したペルオキシダーゼを触媒に用いるフルオレセイン化学発光による過酸化水素の定量

Files in This Item:
bunseki.54-569.pdf221.78 kBPDFView/Open
Please use this identifier to cite or link to this item:http://hdl.handle.net/2115/71714

Title: リポソームに内封したペルオキシダーゼを触媒に用いるフルオレセイン化学発光による過酸化水素の定量
Other Titles: Determination of Hydrogen Peroxide by Fluorescein Chemiluminescence Catalyzed with Horseradish Peroxidase Encapsulated in Liposome
Authors: 上舘, 民夫1 Browse this author
石田, 良樹2 Browse this author
谷, 博文3 Browse this author →KAKEN DB
石田, 晃彦4 Browse this author
Authors(alt): Kamidate, Tamio1
Ishida, Yoshiki2
Tani, Hirofumi3
Ishida, Akihiko4
Keywords: chemiluminescence
liposome
peroxidase
hydrogen peroxide
fluoresein
Issue Date: Jun-2005
Publisher: 日本分析化学会
Journal Title: BUNSEKI KAGAKU
Volume: 54
Issue: 6
Start Page: 569
End Page: 572
Publisher DOI: 10.2116/bunsekikagaku.54.569
Abstract: Fluorescein (FL) and H2O2 rapidly permeated into the inner phase of liposome which trapped horseradish peroxidase (HRP), to initiate HRP-catalyzed FL chemiluminescence (CL) with H2O2. The CL intensity was dependent on the concentration of H2O2. The optimum conditions of charge-type, composition and diameter of liposome in the assay of H2O2 were determined by measuring the CL intensity, to be maximal under optimum conditions. Anionic liposome containing phosphatidylcholine, dimyristoyl-glycero-phosphocholine and cholesterol (Chol) was effective for enhancing the CL intensity and stability of liposome. The CL intensity decreased with an increase in the content of Chol in liposome. The optimal content of Chol was thus determined to be 10 mol%. The effect of the liposome size on the CL intensity was examined by preparing liposomes with a different diameter. The CL intensity increased with an increase in the diameter of liposome. The optimal diameter of liposome was thus determined to be 1000 nm. The logarithmic calibration curve of H2O2 was linear over the range from the detection limit of 4.0 × 10−8 M up to 1.0 × 10−5 M. When HRP trapped in liposome was used as a catalyst, the CL intensity was greater than that observed by using HRP dissolved in the bulk solution in the range of 4.0 × 10−7 M up to 1.0 × 10−5 M of H2O2.
Type: article
URI: http://hdl.handle.net/2115/71714
Appears in Collections:工学院・工学研究院 (Graduate School of Engineering / Faculty of Engineering) > 雑誌発表論文等 (Peer-reviewed Journal Articles, etc)

Submitter: 谷 博文

Export metadata:

OAI-PMH ( junii2 , jpcoar_1.0 )

MathJax is now OFF:


 

 - Hokkaido University