HUSCAP logo Hokkaido Univ. logo

Hokkaido University Collection of Scholarly and Academic Papers >
Graduate School of Information Science and Technology / Faculty of Information Science and Technology >
Peer-reviewed Journal Articles, etc >

Fast calculation method with saccade suppression for a computer-generated hologram based on Fresnel zone plate limitation

Files in This Item:

The file(s) associated with this item can be obtained from the following URL: https://doi.org/10.1364/OE.390547


Title: Fast calculation method with saccade suppression for a computer-generated hologram based on Fresnel zone plate limitation
Authors: Wei, Lingjie Browse this author
Okuyama, Fumio Browse this author
Sakamoto, Yuji Browse this author →KAKEN DB
Issue Date: 27-Apr-2020
Publisher: Optical Society of America
Journal Title: Optics express
Volume: 28
Issue: 9
Start Page: 13368
End Page: 13383
Publisher DOI: 10.1364/OE.390547
Abstract: The computer-generated hologram (CGH) is an ideal 3D technology that can satisfy all the physiological factors of the human eye (such as binocular parallax, focus adjustment and convergence etc.) by simulating the recording part of traditional optical holography with a computer. CGH has a lot of advantages such as being able to be used for animation. However, it also has many disadvantages, and one of them is the large amount of calculation. A saccade is one of a very rapid movement of human eye, and also, it is an ability of the eye to quickly and accurately move from one target to another. This is very critical for reading and involves very precise and specific eye movements. Saccades normally happen at a frequency of 2 - 8 times per second in daily life without our being conscious, and their peak angular speed can reach 900 degrees/second. However, saccades can also be initiated by an expected stimulus such as looking from one object to another, and they last from 20 - 200 ms depending on their amplitude. In addition, our visual information is suppressed while saccade occurs. In this paper, to realize the fast calculation of CGHs, a new method is proposed that uses saccades to reduce the amount of CGH calculation without any negative effects on observers viewing CGH reconstruction images. We increased high-speed calculation by at least 4 times through Fresnel zone plate limitation and 4.64 times through saccade suppression. (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Rights: © 2020 Optical Society of America. Users may use, reuse, and build upon the article, or use the article for text or data mining, so long as such uses are for non-commercial purposes and appropriate attribution is maintained. All other rights are reserved.
Type: article
URI: http://hdl.handle.net/2115/78616
Appears in Collections:情報科学院・情報科学研究院 (Graduate School of Information Science and Technology / Faculty of Information Science and Technology) > 雑誌発表論文等 (Peer-reviewed Journal Articles, etc)

Export metadata:

OAI-PMH ( junii2 , jpcoar_1.0 )

MathJax is now OFF:


 

 - Hokkaido University